G

Tuesday, July 1st, 2025 2:37 PM

Internet Connection Issue

Hi, there. I’m experiencing issues with my internet connection, especially in the mornings when the connection becomes intermittent.


Modem Model

Arris S33


Issue Summary

Multiple occurrences of "Started Unicast Maintenance Ranging - No Response received - T3 time-out" along with "Dynamic Range Window violation" and "RNG-RSP CCAP Commanded Power Exceeds Value Corresponding to the Top of the DRW" errors indicating issues with upstream ranging and power levels.

Primary Issue: Frequent disconnects and degraded internet performance due to upstream communication failures.

Summary of Observed Issues

Type

Details

T3 Timeouts

Unicast Maintenance Ranging - No Response received

T4 Timeouts

No Unicast Maintenance opportunities received

Dynamic Range Violations

Modem transmit power exceeds or falls below acceptable range

UCD Errors

UCD invalid or channel unusable — upstream channel instability

Profile/Diplexer Errors

Repeated ignored or failed mode change requests between modem and CMTS

Signal Levels

Downstream

Metric

Observed Value

Ideal Range

Power

+8 to +10 dBmV

–7 to +7 dBmV (optimal)

SNR

43–44 dB

> 35 dB (good)

Errors

Up to 25,000 uncorrectables per channel

Should be near zero

Upstream

Channel

Frequency

Power

17

16.4 MHz

46.8 dBmV

18

22.8 MHz

47.0 dBmV

19

29.2 MHz

46.3 dBmV

20

35.6 MHz

46.3 dBmV

Note: Upstream power is borderline too high. Ideal is 38–45 dBmV; 47 dBmV indicates resistance or return path issues.

Sample Error Logs

- Started Unicast Maintenance Ranging - No Response received - T3 time-out

- Received Response to Broadcast Maintenance Request, But no Unicast Maintenance opportunities received - T4 time out

- RNG-RSP CCAP Commanded Power Exceeds Value Corresponding to the Top of the DRW

- Dynamic Range Window violation

- UCD invalid or channel unusable